  • Designed for: RTD PT100 & Thermocouples (Universal input)
  • Output: Signal 4-20mA two wires
  • Configurable measuring ranges
  • Large ambient temperature range
  • Compact and inexpensive
  • Sensor Range: -200 to 850 °C [18 to 390 Ω]
  • Minimum Span*¹ : 25 °C
  • Measurement Accuracy: ± 0.01 % FRI*³ ± 0.05 % rdg
  • Thermal Drift Zero: 0.008 °C/°C
  • Excitation Current: 300 to 550 µA
  • Span: 0.01 %/°C
  • Accuracy: (±0.1%) of Span
  • Maximum Lead Resistance: 50 Ω/leg
  • Lead Resistance Effect: 0.002°C/Ω
  • Size: DN3-DN3000mm (1/8”~120”)
  • Accuracy: ±0.5% of reading,velocity >0.3 m/s
  • Velocity: 0.1-15 m/s
  • Signal Output: 4~20 mA, pulse HART
  • Power Supply: AC85~250V, DC20V~36V
  • Sizes: M-5®, M-7®, M-10®, M-15®, M-25®, M-30®, M-40®, M-60®, M-80®
  • Max Capacity: 800 GPM / 3,028 LPM (180 M3/hr)
  • Max Pressure: 150 PSI / 10.3 Bar / 1034 kPa
  • Max Viscosity: 30-1,500,000 SSU, or 1cP to 325,000cP
  • Temperature Range: -40°F to 160°F
  • Linearity: 0.5%
  • Repeatability: 0.2%
  • Accuracy: ±1% of reading at rates>0.2 mps
  • Response Time: 0-999 seconds, user-configurable
  • Velocity: ±32 m/s
  • Pipe Size: 20mm-6000mm
  • Size & Process Connection: DN4, 6, 10, 15, 20, 25, 32, 40; Thread connection, DN15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 200, Flange connection
  • Accuracy/Range ratio: ±0.5%R; 1:10; 1:15; 1:20
  • Sensor Material: SS304, SS316(L)
  • Output: Pulse, 4-20mA, HART
  • Power Supply: A: +24VDC, for 4-20mA , pulse, RS485 output
  • B: 3.6 V lithium battery, battery voltage: 2.0 V ~3.0 V
  • Fluids Measured: Steam, Gases, and Liquids
  • Flow Range: 10:1 turndown
  • Accuracy: ±1.0% & ±1.5% &± 2.5%
  • Max. Process Temperature: 150℃ – 350℃
  • Nominal Operating Pressure: DN15DN50:4.0Mpa, DN65 DN200:1.6Mpa
  • Max. Pressure Rating: DN15:32Mpa; DN25:25Mpa; DN50:20Mpa, DN80:10Mpa; DN100:6.4Mpa, DN125 DN150:4.0Mpa
  • Fluids Measured: Steam, Gases, and Liquids
  • Flow Range: 30:1 turndown
  • Liquids: 1.0 ft/s (0.3 m/s) Velocity Min. 30 ft/s (9.14 m/s) Velocity Max
  • Digital Communications: HART, Modbus, Profibus DP, Foundation Fieldbus, BACnet, USB, RS-232 Hazardous
  • Area Approvals: CE, cFMus, ATEX, PED, IECEx
  • Medium: Gas (except acetylene)
  • Pipe Range: DN100-DN4000, DN10-DN2000
  • Velocity: 0.1~120 Nm/s
  • Accuracy: ±1% , ±2.5%
  • Working Temperature: -40℃~+220℃
  • Working Pressure: ≤2.5 MPa, ≤4.0 MPa
  • Max. flow rate: 200kg/min
  • Wetted parts: Stainless steel 316L
  • Sensor housing: Stainless steel 304
  • Fluid temperature: -200~200°C
  • Temp. Accuracy: ±1°C
  • Operating Voltage: AC85~265V, DC24V